Welding Cable Size Chart: 2 AWG, 1/0, 2/0 and 4/0

Welding cable is sized in AWG, and a smaller number means a thicker cable. As a typical guide, 2 AWG carries about 150 to 200 A on short leads, 1/0 about 200 to 300 A, 2/0 about 250 to 350 A and 4/0 400 A and up. Use the next size up for long leads, because voltage drop and heat rise with length. These figures are typical, so follow the cable size in your welder’s manual.

Welding cable sizes at a glance

Cable sizeTypical current (short leads)Typical use
6 or 4 AWGUp to about 100 to 150 ASmall home machines, short leads
2 AWGAbout 150 to 200 AHome stick and MIG welders
1/0About 200 to 300 AHeavier home and farm welders
2/0About 250 to 350 AShop machines, longer leads
3/0 and 4/0350 to 400 A and upIndustrial welding, long runs

Makers and cable suppliers publish their own charts, and the safe current also depends on duty cycle, ambient temperature and the insulation rating. When the table and your welder’s manual disagree, use the manual.

How AWG sizes work

AWG numbers run backwards: 6 AWG is thinner than 4 AWG, which is thinner than 2 AWG. The next size past 1 AWG is 1/0 (one-aught), then 2/0, 3/0 and 4/0, and each step is thicker. That is why 2/0 is a much heavier cable than 2 AWG, even though the numbers look alike.

How cable length changes the size

The cable carries the current out to the work and back through the ground lead, so the electrical length is about twice the distance to the work. A long cable has more resistance, which drops voltage, heats the cable and weakens the arc. Move up one size for leads longer than about 50 ft, and use the shortest leads that reach the job.

What to look for in welding cable

  1. Copper conductor, with many fine strands so the cable stays flexible.
  2. A flexible insulation rated for welding, such as EPDM or neoprene, that resists heat, oil and abrasion.
  3. A voltage rating of at least 600 V.
  4. Clean, tight lugs and connectors rated for the cable size. A loose connector heats up more than the cable does.

Connectors, clamps and holders

The electrode holder and ground clamp must be rated for the machine’s current. Many machines use Dinse-style connectors, so match the connector to the machine and the cable size. Crimp or solder lugs properly and cover them with heat-shrink or insulation.

Safety

Check cable for cracked insulation, exposed copper, loose lugs and hot spots. A cable or connector that gets hot during welding is too small, too long or loose. Replace damaged cable, keep leads off wet ground and away from sharp edges, and read welding safety tips.

For machine amperage ranges, see stick welders and 7018 welding rod amperage, and for what else to buy for a home shop, see welding tools for a home shop.

Frequently asked questions

What size welding cable do I need for 200 amps?

Typically 1/0 for leads of about 50 ft or less at moderate duty cycle, and 2/0 for longer runs or heavy use. The welder's manual gives the cable size for its rated output.

Is a bigger welding cable better?

Thicker cable drops less voltage and runs cooler, but it costs more and is stiffer. Match the size to the current and the length, and don't go smaller than the maker recommends.

Is 2/0 welding cable the same as 2 AWG?

No. 2/0 (pronounced two-aught) is much thicker than 2 AWG. The aught sizes 1/0, 2/0, 3/0 and 4/0 are larger than 1 AWG.

Can I use copper or aluminum welding cable?

Copper is the standard because it carries more current for its size and holds up to flexing and connectors. Aluminum cable needs a larger size for the same current and is not common for welding leads.